| Sign In | Join Free | My insurersguide.com |
|
Description : 1212 Fixed Inductors RoHS
Mfr. Part # : GCRH2D14A-2R2NC
Model Number : GCRH2D14A-2R2NC
Package : 1212
The GCRH2D14A series is a type of electronic component manufactured by Shenzhen Glorious Electronic Co.,Ltd. This product is designed for various applications requiring specific electrical characteristics, as detailed in the accompanying specifications.
| Item | Specification | Condition |
| Bending test | Change from an initial value L : within10% | Apply pressure gradually in the direction of the arrow at a rate of about 0.5mm/s until bent depth reaches 3mm and hold for 305s. |
| Adhesion strength | Change from an initial value L : within10% | A static load using a R0.5 pressing tool shall be applied the arrow and to the body of the specimen in the direction of the arrow and shall be hold for 605s. Measure after removing pressure. |
| Vibration | Change from an initial value L : within10% | The specimen shall be subjected to a vibration of 1.5mm amplitude, sweep frequency 10~55Hz (10Hz to 55Hz to 10Hz in a period of one minute) for 1 h in each of 3(X,Y,Z) axes. |
| Mechanical shock | Change from an initial value L : within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. The specimen must be fixed on test board. Three successive shock shall be applied in the perpendicular direction of each surface of the specimen. |
| Free fall test | Change from an initial value L : within10% | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. |
| Solder ability | New solder shall cover 90% minimum of the surface immersed. | Terminals shall be immersed for 5 to 10 seconds in flux at room temperature. Dip sample into solder bath containing molten solder at 2455for 30.5 seconds. |
| Resistance to soldering heat | Change from an initial value L : within10% | Reflow soldering method: Preheat 150~180 9030s, Peak temp 260 (230min , 3010s). The specimen shall be subjected to the reflow process under the above condition 2 times. Test board shall be 0.8mm thick. Base material shall be glass epoxy resin. Measurement: The specimen shall be stored at standard atmospheric conditions for 1 h in prior to the measurement. |
| Dielectric strength | Without damage. | 100V DC shall be applied for 60s between the terminal and the core. |
| Insulation resistance | 100mor more. | 100V DC shall be applied between the terminal and the core. |
| Low temperature | Change from an initial value L : within10% | After stored at a temperature of -40 3for 500 12h. The specimen should be measured, then it should be measured under normal temperature and humidity in 1h~ 2h hours. |
| Dry heat | Change from an initial value L : within10% | The specimen shall be stored at a temperature of 852for 500 12h. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| Dump heat | Change from an initial value L : within10% | The specimen shall be stored at a temperature of 602with relative humidity of 90 ~ 95% for 500 12h. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| Temperature cycle | Change from an initial value L : within10% | The specimen shall be measured after 500 continuous cycles of temperature change of -40for 30 min and 85for 30 min with the transit period of 2min or less. Then it shall be stabilized under standard atmospheric conditions for 1 h before measurement. Measurement shall be made within 1h~ 2h. |
| Temperature drift | Inductance temperature coefficient 2000 ppm/or less | To be measured in the range of -25to 85. |
| Operating temperature range | -40 ~ + 125 | Including the product's heating temperature. |
| Storage temperature range | -40 ~ + 85 *( -40 ~ + 60) | In packing state. |
| Customer's Part No. | Part NO. | Center Inductance Lo (uH) | Test Frequency (Hz/v) | DC Resistance (m) max. | Saturated Current Isat (A) Max. L/L-35% |
| GLE | GCRH2D14A-1R5NC | 1.5 | 100KHz/1v | 63 | 1.80 |
| GLE | GCRH2D14A-1R8NC | 1.8 | 100KHz/1v | 75 | 1.65 |
| GLE | GCRH2D14A-2R2NC | 2.2 | 100KHz/1v | 94 | 1.50 |
| GLE | GCRH2D14A-2R7NC | 2.7 | 100KHz/1v | 106 | 1.35 |
| GLE | GCRH2D14A-3R3NC | 3.3 | 100KHz/1v | 125 | 1.20 |
| GLE | GCRH2D14A-3R9NC | 3.9 | 100KHz/1v | 138 | 1.10 |
| GLE | GCRH2D14A-4R7NC | 4.7 | 100KHz/1v | 169 | 1.00 |
| GLE | GCRH2D14A-5R6NC | 5.6 | 100KHz/1v | 188 | 0.95 |
| GLE | GCRH2D14A-6R8MC | 6.8 | 100KHz/1v | 213 | 0.85 |
| GLE | GCRH2D14A-8R2MC | 8.2 | 100KHz/1v | 281 | 0.80 |
| GLE | GCRH2D14A-100MC | 10 | 100KHz/1v | 294 | 0.70 |
| GLE | GCRH2D14A-120MC | 12 | 100KHz/1v | 394 | 0.62 |
| GLE | GCRH2D14A-220MC | 22 | 100KHz/1v | 774 | 0.42 |
| GLE | GCRH2D14A-330MC | 33 | 100KHz/1v | 1200 | 0.40 |
Inductance Tolerance: J =5% K =10% L =15% M = 20% N=30% (Specifications are subject to actual product.)
This product complies with RoHS regulations, restricting the use of Lead, Mercury, Cadmium, Hexavalent chromium, PBB, and PBDE. Additionally, it prohibits the use of Ozone Depleting Substances (ODS) such as CFCs, Halon, Carbon tetrachloride, and Trichloroethane.
|
|
Electronic component GLE GCRH2D14A-2R2NC with specifications ensuring durability and RoHS compliance Images |